- Auto-Calibration for optimum conditions
- Precise control performance and high dynamic response
- Easy operation with four key pads and full text graphical LCD
- Single and double acting actuators
- Low air consumption due to electric microvalve
- Pressure regulator built in to eliminate variations in supply air pressure
- Problem-free characteristics on very small actuator
- Economical energy saving
- Extremely Vibration Resistant Design
- High resistance against shock and vibration
- Mounting on linear actuators according to IEC 534
- Mounting on rotary actuators according to VDI / VDE 3845 |
| |
 |
- Position transmitter (4...20mA output signal)
- Two alarm limits (Min., Max)
- Gauge block with two stainless pressure gauges
- Explosion proof type (Exd ¥±B T6,Exia ¥±C T6)
- HART communication (FSK) |
|
 |
|
|
SSL |
SSR |
Linear Type |
Rotary Type |
Single |
Double |
Single |
Double |
Input Signal |
4...20mA, 2-wire |
Voltage Drop |
8.5V DC @ 20mA (425§¤) |
Min./Max. Current |
3.6mA / 50mA |
Air Supply Pressure |
1.4...7.0bar(20...100psi) / filtered compressed dry and non-oiled air |
Output Pressure |
0...100% supply air pressure / single or double action |
Shut-Off Value |
Range 0...5% of position signal |
Air Consumption |
0.08N§© / h at 1.4bar (20psi) supply |
| Hummidity Limits |
<90% RH,non-condensing |
| Stroke | Angle |
5..80mm (max. up to 150mm) |
40...90¢ª(max.up to 100¢ª) |
| Adjusted Speed |
Range 1...200 (Low 1, High 200) |
| LCD Indication |
4-digit LCD indicator |
| Scan Time |
2§Á |
| Valve Action |
Position 0...100% / Direct action (DA) / Reverse action (RA) |
| Characteristic Curve |
Linearity <= 0.3% F.S/ Sensitivity <= 0.2% F.S/ Hysteresis<=0.2% F.S |
| Temperature Limits |
Operation : -20...70¡É |
| Protection Class |
IP66, Intrinsic Safety (Exia), Flameproof (Exd) |
| Case Material |
Aluminum diecast |
| Electrical Connections |
2¡¿G 1/2 or NPT 1/2 |
| Pneumatic Connections |
Rc 14 or NPT 1/4 |
| Weight |
2.3kg / with pressure gauge block |
|
| |
 |
 |
|
 |

¨ç Mount the positioner to the control as shown below
¨è Connect the feedback lever to control valve stem at position where the angle between the valve stem and the feedback lever becomes 90¢ª as shown below when the input signal is to 12mA (50%)
¨é Stroke range for the best performance should be 5~80mm and the operating angle of the feedback lever should be maximum 45¢ª to carry out accuracy perfectly |
 |
 |
 |
|
 |
 |
|

¨ç Mount the multi-tupe barcket to the actuator as shown below
¨è Confirm the rotating direction of the actuator for air piping (see catalog and manual for details)
¨é Confirm if the feedback lever shaft "A" is placed in the orifice of the fork lever "B" and they are in perfect alignment with a rotary actuator output shaft |
 |
 |
 |
|
 |
 |
|
 |
|
 |
| Confirm the rotating direction of the actuator and connect the air lines as shown below |
 |
| |
| |
Spring Return |
Double Acting |
| Reverse Acting |
Out1:piped, Out2:plugged |
Out1:piped to Actuator port A, Out2:piped to Actuator port B |
| Direct Acting |
Out1: plugged, Out2: piped |
Out1:piped to Actuator port A, Out2:piped to Actuator port B |
|
| |
 |
 |
| |
 |
 |
| |
 |
| |
| Parameters |
Descriptions |
Functions |
Initial value |
| INPU |
Input signal |
4...20mA or 20...4mA |
4-20 mA |
| SPAN |
Span range |
0...100% span adjustment |
100% |
| ZERO |
Zero-up |
Position Zero up and down 0...99% |
0% |
| R/DA |
RA/DA |
Reverse or direct acting |
RA |
| L/E.Q |
Linear/E.Q% |
Linear, E,Q%(1:25 or 1:50) |
Linear |
| SPLT |
Split range |
4...12mA or 12...20mA |
4-20mA |
| SHUT |
Shut-off |
Valve shut off at 0...5% |
0% |
| P-GN |
P-Gain |
Proportional gain value |
Auto setting |
| I-GN |
I-Gain |
Integral gain value |
Auto setting |
| D-GN |
D-Gain |
Differential gain value |
Auto setting |
| ALAM |
Alam limit low,high |
AL1L /AL1H,AL2L /AL2H |
0-10%,90-100% |
| SPED |
Speed control |
1...200 |
200 |
| DIGN |
Display Digit |
Move to one or two decimal places |
1 |
|
| |
 |
¨ç Push MODE key for more than 5 seconds, and Auto Calibration will start
¨è The time required for this process may be different according to actuator volume, but it generally takes about 2~3 minutes |
 |
| |
 |
 |
| |
 |
Note that input signal should be provided for measurement of output signal.
¨ç With a mA loop calibrator Select Measurement mode and connect £« to 4 and £ to 5
¨è With a mulitimeter tester(mA)
|
 |
| ZERO / SPAN of position feedback will be automatically set after Auto Calibration . |
| |
 |
 |
|
Note that the alarm limits were already set at the factory to 0...10%for AL1(L,H)and 90...100%forAL2(L,H). Please refer to the manual for details. |
| |
 |
 |
| Description |
Code |
Description |
Code |
| Actuator Operation: |
L: Linear Type
R: Rotary Type |
Pressure Gauge Block: |
N: None
1: 6bar (90psi)
2: 10bar (150psi) |
Protection Class:
|
F: Flameproof(Exd ¥±B T6)
I: Intrinsic Safety(Exia ¥±B T6)
W: Weatherproof to IP 66 |
| Position Feedback : |
N: None
O: Position Transmitter
(4~20mA Output Signal)
L: Two Alarm Limits
M: O+L |
Feedback Lever:
Linear Type
Rotary Type |
A: Stroke (5~40 mm)
B: Stroke (5~80 mm)
C: Stroke (up to 150 mm)
F: Fork Lever (standard)
N: Namur Shaft (direct mounting) |
| HART Communicatoin: |
N: None
H: HART Comm |
| Mounting Bracket : |
N: None
L: DIN/IEC534(for SSL)
R: DIN VDI/VDE3845(for SSR) |
|
| |
 |
| unit : mm |
 |
 |
| unit : mm |
 |
 |
| |
 |
| unit : mm |
 |